A rigid structure which supports and feeds lighting, in single phase

or three phase.

Conforms to BS EN 60439-2

Conductors are protected by an auto-extinguishing sheath. Body

is hot dip galvanised steel to BS EN 10142, which forms the

protective earth.

IP55 (according to BS EN 60529)

Trunking lengths

Lengths with 2 or 3 tap-off outlets (spaced every

1.0m) are supplied with outlet covers fitted.

Lengths with 6 tap-off outlets (spaced every 0.5m) are

supplied with 3 tap-off covers fitted.

With 3 + 3 outlets

Tap-off outlets are spaced every 1·0m on both sides (6 positions per 3m length)

With 5 outlets on one side

Suitable for rising mains

Without outlets

Feeder lengths. A tap-off point is only possible on the junction between two lengths

Trunking lengths – 3 m

For vertical runs or riser applications. Special lengths between 400mm and 3m are available upon request.

IP40 protection when installed with outlets facing up. IP52 protection when

installed edgeways. IP55 protection when using tap-off outlet covers and

appropriate accessories.

Flame retardant in compliance with IEC 60332-3. Fully compliant with

BS EN 60439-2.

Rated currents are at an average ambient temperature of 40

º

C (over and

above the required standard of 35

º

C).

LIGHT DUTY

LB SINGLE SIDED LIGHTING BUSBAR

Conforms to BS EN 60439-2. Casing manufactured from Senzimir quality

galvanised steel suitable for use as a protective earth.

IP40 as standard, increasing to IP55 with use of appropriate accessories.

63 A

Cat. Nos

Length

(m)

Outlet

points

Weight

(kg)

51530101 3 3 + 3 7.890

51530116 2 2 + 2 5.260

51530115 1.5 1 + 1 3.945

51530114 1 1 + 1 2.630

51530112 < 1.5 –

51530113 > 1.5 –

Trunking lengths

Tap-off outlets are spaced every 1.0 m on both sides and are fitted with shutters

to prevent accidental contact with live parts.

Expansion joints are not required.

Available in 100A and 160A with Fire Barrier / with Thrust unit

LOWAND MEDIUM POWER 63/100/160A

MS DOUBLE SIDED BUSBAR

MEDIUM POWER 160 - 1000A

MR MEDIUM RATING BUSBAR

Complete range available

ask for details of accessories and components or

for a competitive quote

63 A with fire barrier

For vertical runs or riser applications exceeding 20m

Lengths are fitted with a fire barrier and are used

to pass through fire-resistant walls

In accordance with DIN 4102-9 and EN 1366-3

63 A with thrust unit

For vertical runs or riser applications exceeding 20m

51530131

3 3 + 3 7.990

51530141

3 3 + 3 7.890

Aluminium Copper

Rating (A)

Weight (kg)

Copper Aluminium

50400101

160

19.9

50400102 55400102 250

20.9

25.7

50400103 55400103 315

22.8

28.1

50400104 55400104 400

33.8

36.9

50400108

500

37.5

50400105 55400105 630

41.7

56.0

50400106 55400106 800

44.3

72.1

55400107 1000

83.7

50400251

160

19.9

50400252 55400252

250

20.9

25.7

50400253 55400253

315

22.8

28.1

50400254 55400254

400

33.8

36.9

50400258

500

37.5

50400255 55400255

630

41.7

56.0

50400256 55400256

800

44.3

72.1

55400257 1000

83.7

Aluminium Copper

Rating (A)

Weight (kg)

Copper Aluminium

50400241

160

19.9

50400242 55400242 250

20.9

25.7

50400243 55400243

315

22.8

28.1

50400244 55400244 400

33.8

36.9

50400248

500

37.5

50400245 55400245 630

41.7

56.1

50400246 55400246 800

44.3

72.1

55400247 1000

83.7